3.1 Quick operation guide

The BWT PERMAQ
compact 2 - 6 devices could be controlled and parameterised with the control unit.
®
The display of the RO unit shows after the starting phase all currently measured operating values.

3.2 Function keys and display elements

Pressure permeate:
Pump pressure:
Permeate flow:
Status displays:
READY ; PAUSE ;
Feed water temperature:
WORKING, FLUSH
Permeate conductivity:
Fig. 4: Display: with activated detail menu
By pressing the [ON/OFF] button the device switches
from Ready to Pause or ON/OFF.
(Arrow up) button Scrolls through the menu
[ ]
pages upward or increases the value of the
parameter presently shown on the display.
(Arrow down) button Scrolls through the menu
[ ]
pages downward or decreases the value of
the parameter presently shown on the display.
Confirmation button Confirmation of the
[ ]
parameter presently shown on the display and
performs partially (analogy to each of the units
mode) a reset in case of alarms and/or failures.
34
4 Control keys for the menu and parameter
selection [O], [ ], [ ], [ ]
General status:
μS/ppm: When the RO unit is in production, the value of
conductivity in
μS
»
with the activation of the detail screen by tapping the
arrow keys.
ready:
"READY" for a new consumption demand.
In the online mode the unit starts automatically
when the permeate pressure falls below the
presetted starting pressure.
RO unit stops the permeate production.
pause:
Observe: The unit doesn't start in case of
a new emerging permeate demand.
Only in the mode "PAUSE" is your RO unit
programmable.
working: RO unit is in production ... "WORKING".
By pressing the [ON/OFF] button the production
is interrupted and the "PAUSE" message appears,
by a repeated pressing the production start again.
The RO unit rinses ... "FLUSH" and switches after
flush:
that automatically to the operating step "READY".
Optionally available, Item no. 812847:
The RO unit can be equipped with the additional
"EXT. PAUSE":
I/O installation kit, started and stopped due to the triggering of
an external NO potential free signal.
READY ; PAUSE ;
device [ON/OFF]
or TDS in
can be shown,
ppm
«
»
«

Publicité

loading

Ce manuel est également adapté pour:

Permaq compact 4Permaq compact 6