6.3 Inputs and outputs
The following can be connected to the Soft-Control controller if required:
Dosing output
The input and output pulse of the water meter have the same form. Max. 5 V, 5 mA DC
Regeneration start
If the switch connecting terminals 33 and 34 is closed, the unit will regenerate.
Regeneration signal
The regeneration signal output (terminals 31 and 32) is short-circuited while the unit regenerates. Max. 5 V, 5 mA DC
Pressure switch (optional)
If a pressure switch is built into the untreated water pipeline, regeneration is stopped if there is a pressure drop during regeneration and restarted
when there is enough water pressure.
6.2 Quick guide to operation
Confirms
entries
Moves cursor
Setting the time and date
Change language
Actuating regeneration,
column change and
quick flushing
36
Moves cursor,
changes entries
The Browse button toggles
between the Operating and
Selection display
Selection display
Operation display
l / h
Time
Current softened water supply
This column is in
operation
Setting the hardness of
untreated and blended
water
After-sales service staff
only