TROUBLESHOOTING
Trouble
The motors do not work; no warning led turns on.
The machine does not move.
(Only for Adfi nity™ X20R)
The warning leds (76) fl ash simultaneously.
The brushes do not work, the red warning led is
on.
Insuffi cient recovery water vacuuming.
Insuffi cient solution fl ow to the brushes.
Marks caused by the squeegee.
NOTE
The machine cannot operate without the battery charger.
In case of battery charger malfunction, contact an authorized Service Center.
For further information, refer to the Service Manual, available at any Advance Service Center.
The battery connector is disconnected.
The batteries are completely discharged.
The machine has been turned on by using
the ignition key and by keeping the paddle
pressed.
The brush deck motor is overloaded.
The batteries are discharged.
The recovery water tank is full.
The hose is disconnected from the squeegee. Connect.
The vacuum grid is clogged or the fl oat is
stuck closed.
The squeegee is dirty or the squeegee blades
are worn or damaged.
The tank cover is not correctly closed, or the
gasket is damaged, or the compensation hole
is clogged.
The solution/clean water fi lter is dirty.
The tank is dirty (the drain hole is clogged).
The EcoFlex™ system tank is dirty/encrusted. Drain.
There are debris under the squeegee blades.
The squeegee blades are worn, chipped or
torn.
The squeegee has not been balanced with the
handwheel.
Adfi nity™ 17ST - 20ST - X20R
INSTRUCTION FOR USE
Possible Cause
9096912000(4)2010-11
ENGLISH
Remedy
Connect.
Charge the batteries.
Turn the ignition key to "0", then try to start the
machine without pressing the paddle.
Use a less aggressive brush suitable for the
fl oor to be cleaned.
Charge the batteries.
Empty the tank.
Clean the grid or check the fl oat.
Clean and check the squeegee.
Close the cover correctly, or replace the
gasket or clean the compensation hole.
Clean the fi lter.
Clean.
Remove the debris.
Replace the blades.
Balance.
25