RECOMMENDED SPARES & ACCESSORIES
Item
Accessory kit - Comprising bag, hose & upholstery tool
Wand (heavy duty)
FAULT DIAGNOSIS
The following simple checks may be performed by the operator. If the machine is still not working, please contact your local Service Agent:
Trouble
Machine is not working
Loss of vacuum suction
Brush not rotating
Machine is not spraying solution
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.
PLEASE REFER TO THE BACK OF THE MANUAL FOR PICTORIAL INSTRUCTIONS
5
Reason
• Lack of voltage/electrical supply
• Recovery tank incorrectly fitted
• Recovery tank lid is incorrectly fitted
• Recovery tank is full
• Vacuum hose is blocked
• Vacuum head blocked
• Brush jammed with debris
• Motor overload cut-out operated
• Can you hear the pump running?
• Blocked jet
• Solution filter is blocked
HC250
05-3406-0000
05-3679-0500
Remedy
• Check fuse *, power cord, plug and socket outlet
• Refit the recovery tank
• Refit the recovery tank lid
• Empty recovery tank
• Check vacuum hose for blockages and signs of damage
• Check vacuum head for blockages and signs of damage
• Check brush for debris and signs of damage
• Reset motor overload cut-out
• If no, please contact your Service Agent.
• If yes, see below.
• Check jet for blockages and signs of damage
• Check solution filter for blockages and signs of damage
08-21