Placing the fi replace
•
The appliance must be placed on a fl oor that is solid enough to hold it.
•
It is forbidden use and/or to place fl ammable materials, such as curtains, in the vicinity of the appliance; it is safe to keep them
at a distance of at least 1.5m.
Installing the reducer
Depending on the length and shape of the concentric channel system Ø
100 - Ø 150 mm and the outlet construction, a restrictor with a diameter
of Ø 40 mm, Ø 45 mm or Ø 60 mm according to the tables on page 26
must be installed in the top of the combustion chamber. The standard
culvert for the fl ue gases is Ø 100 mm.
Ensure that the reducer is properly fi tted. Fitting the reducer
incorrectly may cause defects to the appliance.
GB