GB
IRL
Without compressed-air filling valve
8. Press the pump handle [13] down and turn it clockwise.
► The pump handle is unlocked. (Fig. 10).
9. Generate the required pressure (→ Table 2) in the tank [1] (Fig. 11).
The maximum pressure should not exceed 6 bar (red line on the pressure gauge [16],
Fig. 11). If the maximum pressure is exceeded, the safety valve will engage and
release the excess pressure.
10. Press the pump handle [13] down and turn it counterclockwise.
► The pump handle is locked in place. (Fig. 5).
With compressed-air filling valve (option)
8. Connect the compressed-air hose [17] to the compressed-air filling valve [18]. (Fig. 12).
► Pressure is built up (max. 6 bar (87 psi)).
Ensure that the initial pressure is not higher than 15 bar.
9. When the required pressure has built up (→ Table 2), remove the compressed-air hose
[17].
Spraying
Observe the instructions in the section entitled "Safety".
Operate the device only while it is vertical or suspended upright and nearly vertical.
Avoid allowing drops of spray to drift onto areas that are not being treated.
Observe the instructions of the spray product manufacturer!
1. Suspend
the
(Fig. 13 and/or 14)
To prevent dripping, hold the spray lance up when first spraying and activate the shut-
off valve until no more liquid mixed with air is emerging.
2. Activate the shut-off valve [9] (Fig. 15).
► Spraying may now begin.
3. Make certain the optimum spraying pressure is set (→ Table 2) on the pressure
gauge [16].
Spraying pressure
1,5 bar (21,76 psi)
2,0 bar (29,01 psi)
3,0 bar (43,51 psi)
Table 2. Dependence: spraying rate and spraying pressure
4. If the spraying pressure decreases more than 0,5 bar (7;25 psi) from the optimum level,
pump some more.
If liquid mixed with air emerges from the nozzle, the tank is empty.
AUS
device
from
your
USA
NZ
shoulder
or
place
Spraying rate with fan jet nozzle
0,56 l/min
0,64 l/min
0,78 l/min
15
CDN
IND
it
on
your
back.