10. Specifications
Model
Variable output voltage
Variable output current
Load (0-100%)
Line (170 – 264V AC variation)
Load (10-90%)
Line (170 – 264V AC variation)
Ripple & Noise voltage (rms)
Ripple & Noise voltage (peak-peak)
Ripple & Noise current (rms)
voltage meter
current meter
Input voltage
Full load input current
Efficiency
Switching frequency
Transient Response Time (50-100%)
Power Factor Control (PFC)
Cooling Method
Protections
Special Features
Operating Temperature
Storage Temperature
Dimensions (WxHxD) in mm
Weight
P 1525
Output
1 – 16V DC 1 – 16V DC 1 – 32V DC 1 – 32V DC
0 - 40A
Voltage regulation
Current regulation
150mA
Ripple & Noise
70mA
Meter Type & Accuracy
3 digit LED Display (+/-0,2% + 3 dgt.)
3 digit LED Display (+/-0,2% + 3 dgt.)
Other
3,15A
85,50%
65 - 85kHz
Power factor correction >0,95 at optimal load
Thermostatic Control Fan from Zero to full speed
Overload, Short Circuit by Constant Current, Output
Tracking Over Voltage, Over Temperature
3 User defined VI preset, Remote control V, I and
200x90x255 200x90x325 200x90x255 200x90x315
2,6kg
-39-
P 1530
P 1535
0 – 60 A
0 - 20A
50mV
20mV
200mA
100mA
50mA
5mV
50mV
100mA
30mA
220 – 240V AC 50/60Hz
4,7A
3,1A
85,00%
87,00%
65 - 85kHz
75 - 85kHz
1,5ms
output on-off
0 ... +50°C; RH < 70 %
-10 ... +60°C; RH < 80 %
3,2kg
2,6kg
P 1560
0 – 30A
40mA
40mA
4,5A
86,00%
75 - 95kHz
3,2kg