Method B:
Using two 0-5K Ohm variable resistors
Remark: variable resistors 5KOhm
Remote Socket Pin Assignment for variable resistor
PIN
1
2
3
4
5
6
7
8
Check the output voltage range of the power supply by adjusting the 5Kohm variable resistor.
Short circuit the main output with 10AWG (5,3mm2) wire to check the display for CC setting by
adjusting the variable resistor.
9.2. Remote Output ON/OFF Control (PeakTech 1525/1535)
This remote output on/off control can be activated in any of the modes Normal, Preset, Remote and
Set mode.
1. By default, Pin 5 is open and output is on.
2. Shorting Pin 5 to Pin 4 (ground) and output is off.
3. When output is off, the C.V. & C. C. LED´s will flash. The current output voltage and current
setting will show on the panel meter.
4. You can also adjust the output by voltage & current control knob to your desired value, when
output is off.
Remark: using the 8pin remote plug provided and connect with 22AWG (0,33m2) wires.
Functions
Internal DC +5V
Voltage Adjust
Current Adjust
Ground
Output OFF
N.A.
N.A.
N.A.
-33-
Remarks
Resistor end
Variable part of resistor
Variable part of resistor
Another resistor end
Short to Ground
Pin numbers are
marked on the black
portion.

Publicité