6. Additional Functions
The following steps explain how to use the special features: remote sensing and remote control. You
can use the features at the same time or separately. F position (rear panel).
6.1. Remote Sensing (P 1530)
Take note of the warnings, wrong disconnection sequence will damage the Power Supply
Warning: Never short the Remote Sensing Terminal
Always disconnect Remote Sensing Terminal first.
Connection:
1.
First complete the power connections between power supply and equipment.
2.
Check and make sure the power connections are secure.
3.
Then make connections between Remote Sensing and equipment.
Warning!:
Fig.3 showing connections between Remote Sensing, Power output and Equipment.
The remote sensing wire should be AT LEAST 22AWG (0,33mm2)wire size.
Disconnection: Wrong disconnect sequence will damage power supply
1.
First disconnect the remote sensing connections.
2.
Then disconnect the power connections between the power supply and equipment.
6.2. Control Mode Selection
There are 4 modes, Normal, Preset, Set and Remote Control mode for the power supply.
Slide the Mode Selection Switch (8) P 1525/1535 or (9) P 1530/1560 to your desired Mode.
The power supply is factory preset to Normal Mode with maximum current level CC.
6.3. Normal Mode
This is the factory preset mode and the power supply output V, I are controlled by the dual action
volume knobs.
Push the knobs to toggle the coarse and fine tuning, notice the subtle changes in brightness of related
LED.
Adjust the knobs to your desired values by trying coarse and fine tuning.
To check the preset current level, just turn the Current Knob lightly in any direction.
The display will resume its normal brightness after few seconds to double confirm your adjustment.
Never short the Remote Sensing Terminal
Never connect the Remote Sensing Terminal in reverse polarity
-27-