Time-independent
DHW circulation - Wiring Option A
In this mode, the DHW circulation pump
is enabled by briefly operating the hot
water draw-off point and is shut off by
the built-in thermostat when the preset
DHW circulation return temperature is
reached. The time switch is not used
with this mode (to avoid continuous
operation).
Set function selector (C) to ON.
1 Power supply (230 V - 50 Hz)
2 Flow switch (FLS)
3 Freshwater module primary
pump (HE pump)
4 HE pump PWM signal
5 DHW circulation unit (CIRC
PUMP)
Time-dependent
DHW circulation - Wiring Option B
The DHW circulation pump is started
by a separately adjustable time switch.
DHW circulation stops when the preset
DHW circulation return temperature is
reached. The pump cycling operation is
thermostat-driven. DHW circulation is
disabled outside of the preset periods.
Set function selector (C) to
38
Installing the BSP-ZP DHW circulation
module
=
4
=
2
=
4
.
=
2
~
Circ
5
Pump
Connection of a non-high-efficiency pump; see appro-
priate electrical connection configuration
~
Circ
5
Pump
~
~
1
HE
3
Pump
~
~
1
HE
3
Pump
3064928_201607