CPU BOARD LAYOUT KEY
OPER
GREEN LED
COM
GREEN LED
A
+3V3
RED LED
CLOUD
GREEN LED
RUN
RED LED
B
PWR
RED LED
DIP switch ON = Maintenance in progress
SW2-1
DIP switch OFF = Normal operation
DIP switch ON = Reset codes
SW2-2
DIP switch OFF = Normal operation
C
DIP switch ON = Total reset
SW2-3
DIP switch OFF = Normal operation
DIP switch ON = Not allowed
SW2-4
DIP switch OFF = Normal operation
D
RES
Reset button if pressed for 5 sec
E
EXC
Jumper inserted = Tamper bypassed
F
TAMPER Tamper connector
+
Power positive (13,8 V⎓)
G*
A / B
BUS Data transmission/reception A / B
-
Power negative (GND)
Back-up battery connection cable 12 V⎓
+BAT
H
7Ah MEDEA /32 CPU
-BAT
9Ah / 18Ah CPU MEDEA /64 and /160
+PS
Board power positive (14,4 V⎓)
I
-PS
Board power negative (GND)
USB connector type B. For local connection of a
J
USB-B
PC for programming
USB type A connector. For the connection of a
K*
USB-A
USB memory device for software updates
RJ45 connector. For connecting the control unit
L
LAN
to a LAN or modem/router
M
OPTO 1 Connector for optional interface
* CPU MEDEA /64 and MEDEA /160 CPU only
** For connection of the ER700-RF wireless expansion interface
EN50131
EN50131
EN 50131 grade 2 - grade 3 certified device
GRADE 2
GRADE 3
On = Normal operation
Off = Board not working
Flashing = System start
On = Board not working
Off = Board not working
Flashing = Normal operation
Logic present power (+3,3 V⎓)
On = Cloud connected
Off = No connection to the Cloud
On = Control unit not working
Off = Control unit not working
Flashing = Normal operation
Board power supply present
(14,4m V⎓)
N
OPTO 2 Connector for optional interface
O
OPTO 3 Connector for optional interface
P
BUS
RED LED
Q*
BATT
Clock-calendar back-up battery
+
Power positive (13,8 V⎓)
R**
A / B
BUS Data transmission/reception A / B
-
Power negative (GND)
+
Power positive (13,8 V⎓)
S
A / B
BUS Data transmission/reception A / B
-
Power negative (GND)
+SR
Power output without back-up (14,4 V⎓)
+V1
Power output positive (13,8 V⎓)
-V1
Output power negative (GND)
NC1
Output 1 - relay, contact normally closed
T
NO1
Output 1 - relay, normally open contact
C1
Output 1 - relay, common contact
U2
Output 2 - electric
SAB
SAB input - single-balanced
+V2
PrIO power positive (13,8 V⎓)
-V2
PrIO power negative (GND)
IN1
Input 1, referred to positive
IN2
Input 2, referred to positive
U
IN3
Input 3, referred to positive
IN4
Input 4, referred to positive
IN5
Input 5, referred to positive
IN6
Input 6, referred to positive
+V2
PrIO power positive (13,8 V⎓)
-V2
PrIO power negative (GND)
V*
P7
PrIO 7 – programmable input/output
P8
PrIO 8 – programmable input/output
Flashing = Bus communication
8