Operation in the menu
Querying areas and ignoring detector
zones and faults
Description
If it is not possible to arm the system, the de-
tector that was triggered can be removed
from monitoring (Ignore). Not in compliance
with VdS. Notify 24-hour service after the sys-
tem is disarmed.
Procedure
1. To call up the "AREAS" function from the
menu, see chapter "Calling up and ending
functions".
05: AREAS
2. Call up "AREAS".
By pressing the "ENTER" key, the first de-
tection area is displayed. If the area is not
ready for arming, "NARM" appears in the
display for the center
NARM reasons (reasons for "Not ready for
arming").
AREA
01 = OFF
NARM
3. Call up additional "AREAS".
By pressing the right
areas can be called up consecutively. After
the last area, "AREA 1" reappears in the
display.
AREA
02 = OFF
NARM
4. Calling up NARM reasons. The center
key is used to display the NARM reasons
(reasons for "Not ready for arming").
0005 - 13 = TRIGGE
IGNORE
?
key to call up
key, additional
- 17 -
5. Execute one of the 3 operational steps:
Ignore detectors zones and faults.
If it is not possible to arm the system, a
maximum of one "triggered detector
zone", "Network fault", or "NVU fault" can
be removed from monitoring (Ignore) by
pressing the left
service after the system is disarmed.
Call up additional information.
By pressing the center
tional information for the displayed trig-
gering will be shown for approximately
3 seconds.
Call up additional triggering.
By pressing the right
reasons for failure to arm the area will be
displayed. After the last triggering, the
first triggering reappears in the display.
0010 - 05 = TRIGGE
IGNORE
?
6. The "STOP" key causes a return by one
level.
AREA
02 = ON
NARM
7. The "STOP" key causes a return by one
level. The menu will be displayed.
05: AREAS
key. Notify 24-hour
key, addi-
key, additional