Technical specifications
Power supply ....................................................................................................................100 - 240 V~ 50/60 Hz
Maximum input power in the operation ......................................................................................................6.3 VA
Maximum nominal current.............................................................................................................................15 A
Relay AUX 2 - SPDT - 16 A
Relay DEF - SPDT - 20 A
Relay COOL - SPST - 16 A.......................................................................................(EN60730-1: 12 (9) A 250 V~)
Relay FAN - SPST - 16 A .........................................................................................(EN60730-1: 12 (9) A 250 V~)
Relay AUX 1 - SPDT - 20 A
No. of relay operations .........................................................................................EN60730-1:100.000 operations
Probe temperature range.........................................................................................................-50.0 ºC to 99.9 ºC
Resolution, setting and differential ..............................................................................................................0.1 ºC
Thermometric precision................................................................................................................................±1 ºC
Loading tolerance of the NTC probe at 25 °C............................................................................................±0.4 ºC
Input for NTC probe ...........................................................................................................................AKO-14901
Working ambient temperature ........................................................................................................-10 ºC a 50 ºC
Storage ambient temperature ........................................................................................................-30 ºC to 60 ºC
Protection degree .........................................................................................................................................IP 65
Installation category ....................................................................................................................II s/ EN 60730-1
Pollution degree ..........................................................................................................................II s/ EN 60730-1
Control device classification: Built-in assembly, with Type 1.B automatic operation action feature, for use in clean
situations, logical support (Software) class A and continuous operation. Degree of contamination 2 acc. to UNE-EN
60730-1.
Double isolation between power supply, secondary circuit and relay output.
Temperature during ball-pressure test
Current of radio jamming supression tests ................................................................................................270 mA
Voltage and current as per EMC tests:..................................................................................................207 V, 17 mA
Type of assembly..............................................................................................................................Fixed internal
MODBUS address..........................................................................................................................Shown on label
Dimensions...........................................................................................290 mm (W) x 141 mm (H) x 84.4 mm (D)
Internal buzzer
NO .............................................................. (EN60730-1: 12 (9) A 250 V~ )
NC ................................................................(EN60730-1: 10 (8) A 250 V~)
NO ..............................................................(EN60730-1: 15 (15) A 250 V~)
NC ..............................................................(EN60730-1: 15 (13) A 250 V~)
NO ..............................................................(EN60730-1: 15 (15) A 250 V~)
NC...............................................................(EN60730-1: 15 (13) A 250 V~)
Accessible parts ..........................................................................75 ºC
Parts which position active elements ...........................................125 ºC
32