Configuration - AKO -16524A Guide Rapide

Contrôleur avancé de température pour chambre froide
Masquer les pouces Voir aussi pour AKO-16524A:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Configuration

Condensed programming menu
This allows for the most-used parameters to be quickly configured. Press the SET key for 3 seconds to access it.
Condensed programming menu
OUT OF
PROGRAMMING
Temperature
indication
Parameters
Description
SP
Temperature setting (Set Point)
CE
SELFDRIVE Mode 0=Deactivated 1= Activated
C1
Probe 1 differential (Hysteresis)
d0
Defrost frequency (Time between 2 starts)
d1
Maximum defrost duration (0=defrost deactivated)
d4
Final defrost temperature (by probe) (If P4 ¹ 1)
F3
Status of the fans during the defrost 0=Shut down; 1=Running
A1
Alarm for maximum in probe 1 (It should be higher than the SP)
A2
Alarm for minimum in probe 1 (It should be lower than the SP)
d30
Defrost strategy in SELFDRIVE mode
* According to wizard.
20 sec.
Parameters
OK
3 seg.
Change
parameter
OK
26
IN PROGRAMMING
Values
Change
value
OK
20 sec.
Values Min.
ºC/ºF
ºC/ºF
H.
Min.
ºC/ºF
ºC/ºF
ºC/ºF
1652H4A11 Ed.08
Def. Max.
-50
0.0
99
0
1
1
0.1
2.0
20.0
0
6
96
*
0
255
-50
8.0
C2
0
0
1
A2
99
99
-50
-50
A1
0
5
10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ako-16525a

Table des Matières