3. Sprayer model number is displayed followed by Data
Point 1 which is the unit power on time in hours.
4. Press display button again to display Data Point 2.
Motor run time in hours is displayed.
5. Press display button again to display Data Point 3.
This will be the last error code.
6. To erase last error code, press and hold display button.
7. Press display button again to display Data Point 4. The
software revision is displayed.
8. Press display button again to return to Data Point 1.
9. Turn ON/OFF switch to OFF position to exit Stored
Data.
Cleanup
1. Perform Pressure Relief Procedure.
2. Remove tip guard and Spray Tip. For additional infor-
mation, see separate gun manual.
3. Remove fluid intake and drain tube from paint, wipe
excess paint off outside.
4. Place fluid intake in flushing fluid. Use water for water
base paint and mineral spirits for oil-based paint. Place
drain tube in waste pail.
167
Original instruction