Startup

1. Perform Pressure Relief Procedure.
2. Turn pressure control to lowest pressure.
3. Place fluid intake in paint pail. Place drain tube in
waste pail.
4. Turn ON/OFF switch to ON position.
5. Turn pressure control to QuickFlush to start motor.
Allow paint to circulate through sprayer until paint flows
out the drain tube.
Original instruction
6. Turn prime valve horizontal. Disengage trigger lock.
7. Hold gun against grounded metal waste pail. Trigger
gun until paint appears.
8. Move gun to paint pail and trigger for 20 seconds.
Release trigger and allow sprayer to build pressure. Enga-
ge trigger lock.
High-pressure spray is able to inject toxins into the body
and cause serious bodily injury. Do not stop leaks with
hand or rag.
9. Inspect airless hose and connections for leaks. If leaks
occur, perform Pressure Relief Procedure, then tighten all
fittings and repeat Startup procedure. If there are no leaks
continue with the next step.