Electrical connection
• The installation of this appliance and the connection to the electrical network should be en-
trusted only to an electrician whom is aware of the local regulations and which respects them
scrupulously.
• Protection against the parts under tension must be ensured after the building-in.
• The necessary data for connection are on the stickers placed on the hob casing near the con-
nection box.
• The connection to the main must be made using an earthed plug or via an omni polar circuit
breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
Caution!
This appliance is only to be connected to a network 230 V~ 50 Hz.
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath, at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Mains
230V~1P+N 50Hz
400V~2P+N 50Hz
230V~2P+2N 50Hz
* calculated with the simultaneous factor following the standard TN 60 335-2-6/1990
56
Connection
Cable diameter Cable
1 Phase + N
3 x 2,5 mm²
2 Phase + N
4 x 1,5 mm²
2 Phase + 2N 5 x 1,5 mm²
Protection calibre
H 05 VV - F
25 A *
H 05 RR - F
H 05 VV - F
16 A *
H 05 RR - F
H 05 VV - F
16 A *
H 05 RR - F