Electrical connection
• The installation of this appliance and the connection to the electrical network should be entrus-
ted only to an electrician perfectly to the fact of the normative regulations and which respects
them scrupulously.
• Protection against the parts under tension must be ensured after the builting-in.
• The data of connection necessary are on the stickers place on the hob casing near the con-
nection box.
• The connection to the main must be made using an earthed plug or via an omnipolar circuit
breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example :
circuit breakers, fuses or contactors.
• If the appliance is not fitted with an accessible plug, disconnecting means must be incorporated
in the fixed installation, in accordance with the installation regulations.
• The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or
oven
Caution !
This appliance has only to be connected to a network 230 V~ 50 Hz. Connect always the earth
wire. Respect the connection diagram. The connection box is located underneath at the back of
the hob casing. To open the cover use a medium screwdriver. Place it in the slits and open the
cover.
Mains
230V~ 50/60 Hz (BE)
400V~ 50/60Hz (BE)
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Connection of the hob
For the various kinds of connection, use the brass bridges which are in the box next the terminal.
Monophase 230V~1P+N
Put the 1st bridge between terminal 1 and 2, the 2nd between 4 and 5.
Attach the earth to the terminate "earth", the neutral N to terminal 4 or 5, the Phase L to one of
the terminals 1 or 2.
66
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
2 Phases + N
4 x 1.5 mm²
Cable
Protection
calibre
H 05 VV – F
25 A
H 05 RR – F
H 05 VV – F
16 A
H 05 RR – F