Electrical Connection - BORETTI BKK-76 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical connection

• The appliance may be installed and connected to the mains only by a qualified installer (electri-
cian) who is familiar with the applicable standards.
• After installation the live parts must remain protected.
• The relevant connection details are provided on the model plate and on the connection plate at
the bottom of the appliance.
• The appliance must be isolated from the mains by a multipole circuit breaker. In the open posi-
tion (not connected) the contact gap must be at least 3 mm.
• The appliance must be isolated from the mains by the necessary devices, such as circuit brea-
kers, fuses or contactors.
Caution!
This appliance is designed for connection to a 230 V ~ 50-60 Hz mains network.
Always connect the earth. Follow the connection diagram. The connection box is below the hob.
Open the lid by putting a screwdriver into the 2 slots before the 2 arrows.
Mains
230V~1P+N 50Hz
400V~2P+N 50Hz
230V~2P+2N 50Hz
* calculated with the simultaneous factor following the standard TN 60 335-2-6/1990
Connection of the hob
Use the green/yellow wire as the earth, the blue wire as neutral N and the black wire as phase L.
Monophase 230V~1P+N (not for the Netherlands!)
Put the 1st bridge between terminal 1 and 2, the 2nd between 3 and 4. Attach the earth to the
terminate "earth", the neutral N to terminal 3 (or 4), the Phase L to one of the terminals 1 or 2.
Biphase 400V~2P+N
Put a bridge between terminal 3 and 4. Attach the earth to the terminate "earth", the neutral N
to terminal 3 (or 4), the Phase L1 to the terminals 1 and the Phase L2 to the terminal 2.
Biphase 230V~2P+2N
Attach L1 to terminal 1, L2 to terminal 2, N1 to terminal 3, N2 to terminal 4 and earth to terminal
"earth"
Note! Push the wires right through and tighten the screws firmly.
We cannot be held liable for accidents resulting from incorrect connection or which
could arise from the use of unearthed or poorly earthed appliance.
Connection
Cable diameter Cable
1 Phase + N
3 x 2,5 mm²
2 Phase + N
4 x 1,5 mm²
2 Phase + 2N 5 x 1,5 mm²
Protection calibre
H 05 VV - F
25 A *
H 05 RR - F
H 05 VV - F
16 A *
H 05 RR - F
H 05 VV - F
16 A *
H 05 RR - F