For commissioning, the web interface for qualified
electricians (operator) has to be used. This is here-
inafter referred to as "web interface".
The setup data sheet is divided into two
sections. The first section is intended solely
for qualified electricians and must therefore
be detached before handing it over to the
user.
The following options are available for setting up a
connection to the ECU:

6.5.1 Via USB

u Connect terminal device (e.g. PC, laptop) and
ECU with a USB cable.
1 "6.3 Connections on the ECU" [} 24]
Possible settings
n Change char-
ging mode
n Export char-
ging statistics
n ...
n Setting the
maximum
charging cur-
rent
n Connecting
an external
u Open web browser.
energy meter
n ...
u Enter the user name (operator) and password.
1 Password: See Setup data sheet

6.5.2 Via Ethernet

Requirement(s):
ü The retrofit kit (USB-Ethernet adapter) for net-
1 Installation instructions for the retrofit kit.
u Connect terminal device (e.g. PC, laptop) and
u Configure the network of the terminal device as
u Open web browser.
u Enter the user name (operator) and password.
1 Password: See Setup data sheet
If the driver is not automatically installed un-
der the Windows operating system:
u Navigate to "Control Panel" > "Device
Manager" > "Other devices".
u Right-click on "RNDIS/Ethernet Gadget" >
"Update Driver Software" > "Search for
driver software on the computer" > "Se-
lect from a list of device drivers on the
computer" > "Network Adapter" > "Mi-
crosoft Corporation" > "NDIS-compatible
remote device".
ð The driver is installed.
The web interface can be reached via
http://192.168.123.123.
working is installed.
ECU with an Ethernet cable. To do this, use the
Ethernet port on the USB-Ethernet adapter.
follows:
n IPv4 address: 192.168.124.21
n Subnet mask: 255.255.255.0
n Standard gateway: 192.168.124.1
The web interface can be reached via
http://192.168.124.123.
EN
25