Information on compatible energy manage-
ment systems and the description of the EE-
Bus interface (EEBus Register Table) can be
found on our website: https://
www.chargeupyourday.com/service/com-
patible-systems-and-interfaces/
u Navigate to the menu "Load Management" >
"EEBUS interface" and set the following para-
meters:
Parameter
Setting
EEBUS inter-
u Select "On".
face
Current in case
Current value for charging if
of connection
there is no connection to the en-
failure [A]
ergy management system.
Communica-
Period between disconnection
tion Timeout [s]
from the energy management
system and charging with fall-
back current.
Connect or dis-
n Connect to energy manager:
connect the
The product can connect to
energy man-
the energy management sys-
ager
tem.
n Disconnect energy manager:
The product disconnects from
an existing connection to the
energy management system.
6.10.5Activating the interface (SEMP) for energy
management systems
The tasks described in this section may only
be carried out by a qualified electrician.
As of ECU firmware 5.22, it is possible for the char-
ging station to be controlled by an energy manage-
ment system via SEMP.
34
Information on compatible energy manage-
ment systems and the description of the
SEMP interface (SEMP Register Table) can
be found on our website: https://
www.chargeupyourday.com/service/com-
patible-systems-and-interfaces/
u Navigate to the menu "Load Management" >
"SEMP interface (SMA Sunny Home Manager)"
and set the following parameters:
Parameter
Setting
SEMP interface u Select "On".
Charging Mode Charging mode (Surplus char-
ging, Immediate charging,
Manual configuration).
1 "3.7 Solar charging modes"
[
}
Current in case
Current value for charging if
of connection
there is no connection to the en-
failure [A]
ergy management system.
Communica-
Period between disconnection
tion Timeout [s]
from the energy management
system and charging with the
configured current.
Maximum en-
Maximum amount of energy that
ergy demand
can be charged until the con-
[kWh]
figured time of departure (only
with "Manual configuration").
Minimum en-
Minimum amount of energy that
ergy demand
must be charged until the con-
[kWh]
figured time of departure (only
with "Manual configuration").
Scheduled de-
The time by when the vehicle
parture time
has to be charged (only with
[hh:mm]
"Manual configuration").
6.10.6Setting Autocharge
The tasks described in this section may only
be carried out by a qualified electrician.
Only valid for the PnC-compatible product variants.
11]