IC Maintenance/Troubleshooting

Digital Input Problems
Problem
The wrong input on the screen is changing
when the CNC turns on an input to the IC
No input on the screen is changing when the
CNC turns on an input to the IC
Digital Output Problems
Problem
The IC shows the output turning on but
there is no voltage on the output's emitter
side.
Gas Problems
Problem
The CNC turns on a gas test and no gas
comes out of the torch.
144
Maintenance/troubleshooting
Make sure the inputs are wired to the proper input on the IC.
Make sure the CNC is only sending the 24 VDC from DB37 connector
back to the IC as the input when turning the input on.
Check for voltage on the collector side. If there is a DC voltage there
greater than 10 volts, then call service.
Make sure the plasma gas box and shield gas box have power (green
LED on the same side as the cable connections is lit).
Resolution