Torch Body Removal And Replacement - ESAB Smart Plasmarc 200 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Torch Body Removal and Replacement

WARNING
1. Loosen the worm gear hose clamp so that the torch sleeving can be freed and pulled back up the cable
bundle. Approximately 7" (177.8mm) should be far enough. Unscrew the torch sleeve and slide it back until
the pilot arc connection is exposed.
Handle
2. Disconnect the power cables which are threaded onto the shorter stems at the back of the torch. Note that
one of these connections is left-handed. Unscrew the gas hoses from the torch head assembly by using a
7/16" (11.1mm) and a 1/2" (12.7mm) wrench. Removal of the gas hoses is easier if the power cables are re-
moved first.
7/16" HEX Plasma Gas
Connection
Maintenance/troubleshooting
ELECTRIC SHOCK CAN KILL!
BEFORE PERFORMING TORCH MAINTENANCE:
Turn power switch of the Plasma Console console to the OFF position .
Disconnect primary input power.
1/2" HEX Shield Gas
Connection
Torch Body
1/2" HEX Power Cable & Water
Return Connections
157

Publicité

Table des Matières
loading

Table des Matières