Maintenance; Inspection And Cleaning; Fault Tracing; Ordering Of Spare Parts - ESAB Aristo/Origo Mig 4002c Manuel D'instructions

Masquer les pouces Voir aussi pour Aristo/Origo Mig 4002c:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
7

MAINTENANCE

Regular maintenance is important for safe, reliable operation.
Only those persons who have appropriate electrical knowledge (authorized
personnel) may remove the safety plates.
Note!
All guarantee undertakings from the supplier cease to apply if the customer himself
attempts any work in the product during the guarantee period in order to rectify any
faults.
7.1

Inspection and cleaning

Check regularly that the power source is free from dirt.
The power source should be regularly blown clean using dry compressed air at
reduced pressure. More frequently in dirty environments. Otherwise the air
inlet/outlet may become blocked and cause overheating. To avoid this you can use
an airfilter. The airfilter is an accessory. Ordering number on page 37.
8

FAULT TRACING

Try these recommended checks and inspections before sending for an authorised
service technican.
Type of fault
No arc.
Welding current is interrupted
during welding
The thermal overload trips
operate frequently
Poor welding performance.
9

ORDERING OF SPARE PARTS

Mig 4002c, Mig 5002c, Mig 6502c is designed and tested in accordance with the inter-
national and European standards IEC/EN 60974- -1 and EN 60974- -10,. It is the obliga-
tion of the service unit which has carried out the service or repair work to make sure
that the product still conforms to the said standard.
Spare parts may be ordered through your nearest ESAB dealer, see the last page of
this publication.
mxx02cwe
Check that the mains power supply switch is turned on.
S
Check that the welding current circuit and return cables are
S
correctly connected.
Check that the correct current value is set.
S
Check whether the thermal overload trip has operated
S
(indicated by the orange lamp on the front)
Check the main power supply fuses.
S
Check to see whether the air filters are clogged.
S
Make sure that you are not exceeding the rated data for the
S
power source (i.e. that the unit is not being overloaded).
Check that the welding current circuit and return cables are
S
correctly connected.
Check that the correct current value is set.
S
Check that the correct welding wires are being used.
S
Check the main power supply fuses.
S
- - 12 - -
Actions

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aristo/origo mig 5002cAristo/origo mig 6502c

Table des Matières