Chimney Connection - Napoleon Inspiration ZC Série Manuel D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.2

chimney connection

Chimney installation must conform to both national and local code requirements. The chimney must be lined with
one 2" (51mm) or 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum
and maximum vent lengths are 10ft (3m) and 35ft (10m) respectively. Recommended kits come in 3 lengths:
1-2" (25-51mm) & 1-3" (25-76mm) DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST &
2-3" (50.8-76.2mm) DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:
While the liners must be continuous from the appliance to the chimney cap, to
achieve the needed length, they may be coupled, using an approved coupler.
We recommend that exhaust vents that pass through unheated spaces, such as tall
exterior chimneys, be wrapped in a protective sleeve to minimize condensation and
reverse fl ow symptoms. See the "TROUBLESHOOTING" section for details.
This appliance is approved for use with a 2" (51mm) liner for air intake and a 3"
(76mm) liner for exhaust. For best performance, however, it is recommended to use
two 3" (76mm) liners.
If a 2" (51mm) liner is used for the intake, it may be necessary to adjust the
primary air shutter.
A. OUTSIDE: Slip the one end of a liner a minimum of
2" (51mm) over the sleeve of the air terminal. Secure
using 3 screws. Then seal the joint and screw heads
with high temperature sealant Mill-Pac (not supplied).
Repeat with the other liner.
NOTE: We recommend that the other end of the
exhaust liner be marked to eliminate the exhaust
liner being connected to the intake collar at the
appliance.
B. Gently stretch the liners to the required lengths and
insert into the chimney. Trim and fi t the fl ashing plate
to suit the chimney termination. Place the air terminal
onto the top of the chimney. Make weather tight by
sealing with caulking (not supplied). Fasten to the
chimney with screws and plugs (not supplied).
C. INSIDE: Attach and secure the fl ex liners to the vent
connection assembly using the same procedure as
before, ensuring that the marked exhaust liner is
attached to the exhaust collar.
D. Detach the two screws from the back of the fi rebox
and remove the panel, as illustrated.
E. Reaching in through the appliance, manoeuvre the
vent connection assembly through the openings in the
fi rebox top, taking care not to damage the gasket. In
case of a low ceiling fi replace, the extension should be
removed and reinstalled after the vent connection is
secured to the fi rebox. Attach the restrictor plate to the
centre stud and secure the assembly using the three
studs and 1/4-20 hex nuts.
2-3" (51-76mm) TO 2" (51mm) REDUCER:
GDI-2320KT
VENT KIT 20FT (6m)
GDI-2325KT
VENT KIT 25FT (7m)
GDI-2335KT
VENT KIT 35FT (11m)
GDI-320KT
VENT KIT 20FT (6m)
GDI-325KT
VENT KIT 25 FT (7m)
GDI-335KT
VENT KIT 35 FT (11m)
installation
Exhaust
Intake
VENT
HI-TEMP
CONNECTION
SEALANT
ASSEMBLY
2" (50.8mm)
OVERLAP
EXHAUST
INTAKE
STUDS
VENT
CONNECTOR
eXteNSiON
W415-2359 / 08.22.19
EN
Flashing Plate
2" (51mm)
Overlap
RESTRICTOR
PLATE
9