WARNING
!
• Risk of fire and electrical shock!
• Turn off the gas and electrical power before servicing this appliance.
• Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using
non-listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could
result in a safety hazard and will void the warranty and certification.
• Ensure that the fan's power cord is not in contact with any surface of the appliance to prevent electrical
shock or fire damage. Do not run the power cord beneath the appliance.
• The wire harness provided in the blower kit is a universal harness. When installed, ensure that any excess
wire is contained, prevent it from making contact with moving or hot objects.
1. Turn off the electrical
power and the
gas supply to the
appliance.
2. Remove the fi re
viewing door. Remove
the logs.
3. Detach the two
screws from the back
of the fi rebox and
remove the panel, as
illustrated.
4. Remove the blower access door helf on with the
remaining 8 screws. Replace the blower access
door gasket when changing the blower.
5. Disconnect the two blower wires. Remove the
blower bracket secured with one wing nut and
lock washer. For thermodisc replacement: Remove
the "Z" shaped mounting bracket secured to the
fi rebox wall to the left of the blower. Remove the
thermodisc from the bracket and replace.
6. Replace the blower using the existing bracket.
Slide the vibration reducing pad (A) into the clip (C)
and up against the threaded stud (B) at the other
end. The blower must be able to be positioned
entirely onto the pad.
7. Slide the blower into the clip (C). Secure to the
threaded stud using the existing lock washer and
wing nut. Ensure that the blower does not touch
the fi replace base or the fi rebox.
8. Reconnect the two wires. Holding the replacement
gasket in place, reattach the blower access door
and panel. Replace the logs. Reinstall the fi re
viewing door.
9. Turn the gas supply and electricity back on.
Because the blower is thermally activated, when
turned on, it will automatically start approximately 5-15
minutes after lighting the appliance and will run for
approximately 30-45 minutes after the appliance has
been turned off. Use of the fan increases the output of
heat.
Drywall dust will penetrate into the blower bearings causing irreparable damage and must be prevented from
coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered
by the warranty policy.
white
THERMAL
SWITCH
BLOWER ACCESS DOOR
THERMODISC
BRACKET
ASSEMBLY
B
A
maintenance
BLOWER
SPEED
CONTROL
SWITCH
BLOWER
WIRES
C
21
W415-2359 / 08.22.19
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Inspiration gdizcn-sbInspiration gdizcp-sb

Table des Matières