Installation Of The Control Unit And Sensors (Bc-E); Suitable Control Units; Anschluß Des Steuergerätes Und Der Fühler (Bc-E); Geeignete Steuergeräten - Harvia BC Série Instructions D'installation Et Mode D'emploi

Table des Matières

Publicité

EN
3.4. Installation of the Control Unit and
Sensors (BC-E)
The control unit includes detailed instructions for
fastening the unit on the wall. Install the temperature
sensor on the wall of the sauna room above the
heater. It should be installed on the lateral centre
line of the heater, 100 mm downwards from the
ceiling. Figure 6.
Do not place the supply air vent so that the air
flow cools the temperature sensor. Figure 5.

3.4.1. Suitable control units

Harvia Griffin CG170
Harvia C150
Harvia Xenio CX170
Harvia C90
See the latest control unit models in our website
www.harvia.com.
400-415 V
3N~
1 2 3 4 5 6 7
GRD
N
230-240 V
1 2 3 4 5 6
3~
GRD
L1
230-240 V
1 2 3 4 5 6
1N~
GRD
Figure 10.
Electrical connections of BC heater
Abbildung 10. Elektroanschlüsse des Saunaofens BC
b0
b
a1
a
b0
b
a1
a
b0
b
a1
a
L1 L2 L3
P
L2
L3
L1
N
DE
3.4. Anschluß des Steuergerätes und der
Fühler (BC-E)
In Verbindung mit dem Steuergerät werden genauere
Anweisungen zu dessen Befestigung an der Wand
gegeben. Der Temperaturfühler wird an der Sauna-
wand oberhalb des Saunaofens, 100 mm unterhalb
der Decke auf der Achse in Breitenrichtung des Sau-
naofens angefracht. Abbildung 6.
Luftzufuhr nicht so anbringen, dass sie den
Temperaturfühler abkühlt. Abbildung 5.
3.4.1. Geeignete Steuergeräten
Harvia Griffin CG170
Harvia C150
Harvia Xenio CX170
Harvia C90
Schauen Sie nach den geeigneten Steuergeräten auf
unsere Webseite www.harvia.com.
230 V/
240 V
1N~
230 V
3~
400 V
3N~
Figure 11.
Electrical connections of BC-E heater
Abbildung 11. Elektroanschlüsse des Saunaofens BC-E
31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bc-e sérieBc45Bc60Bc80Bc90Bc45e ... Afficher tout

Table des Matières