Télécharger Imprimer la page

Aprimatic SC6 Mode D'emploi page 4

Masquer les pouces Voir aussi pour SC6:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1.
DESCRIPTION
SC6 is a key selector that controls the WING EVO automatic door functioning.
Positioning the selector rotary key, the user can select one of the 6 functions of
the automation.
SC6 component parts are: one box with black plastic cover and frontal printed plate;
one selector with key (fi xed to the cover); one electronic board with 8 poles terminal
board (fi xed back to the cover).
One connection 8 poles cable (length 4 m) is supplied with a 8 poles femal connector.
Also includes: 4 self-tapping screws 2,9x9,5 mm to fi x the cover; 2 self-tapping screws
3,5x25,4mm and 2 expanding dowels for fi xing the selector.
2.
AVAILABLE FUNCTIONS
fi g. 1
Please refer to
.
Position
Functions
PARTIAL
The operator permits both entry and exit with reduced opening span (entry
OPENING
radar and exit radar are both active).
OPEN
The door opens and remains in the open position (radar and/or photocells
NOT actives).
ENTRY ONLY
The operator permits entry but not exit (the entry radar is active - the exit
radar is NOT active).
NB: Entry Radar = RADAR 1 on the automation central control unit.
EXIT ONLY
The operator permits exit but not entry (the exit radar is active - the entry
radar is NOT active).
NB: Exit Radar = RADAR 2 on the automation central control unit.
TWO-WAY
The operator permits both entry and exit (entry radar and exit radar are
AUTOMATIC
both active).
The door closes and remains in closed.
NIGHT
SERVICE
OPENING/
If an electro-lock is installed, the automation also is blocked.
CLOSING
To disable the night function, turn the key to another position.
Reset
Reset the automation. Then the automation performs a new self-learning.
To avoid unintended activations, the RESET button is inside the 3,5 mm
hole
.
ENGLISH
3. ASSEMBLING AND INSTALLATION
ATTENTION ! The selector is ONLY for indoor installation.
1
Cut to size the cable to connect the selector to the automation central unit.
ATTENTION ! If you need, you can extend the cable to the maz lenght of 15 m.
In this case you must respect the wire colors as specifi ed in
2
Run the cable through the central hole of the box, then connect the eight cables to
the terminal board (on the back of the cover) following the
WIRE COLOR
Red
Green
White
Pink
tab. 1
Grey
Light blue
Brown
Yellow
ATTENTION !
If you the RESET button is NOT used, it is necessary to
short the wire Yellow and the Brown (NC contact). Otherwise the automation
cannot operate.
3
Position the supplied screws into the box holes, then fi x the box on the defi nite
support.
4
Position the cover on the box, then fi x it by means of the supplied screws.
5
Position the printed plate on the box, then fi x it with light pressure.
6
Insert the female connector of the cable into the male JP6 of the automation
control central unit (on the right side of the central unit).
4.
NOTES FOR UTILIZATION
To select a function, make sure that the shaped profi le of the key (a) is positioned
fi g. 2
on the relevant symbol (
The selector has NOT a limit switch position. The key may fully rotate and may be
removed regardless the set position.
To reset the automation it is necessary to insert an awl inside the hole
to press the RESET button.
tab. 2
tab. 2
TERMINAL NUMBER
FUNCTION
1
Partial Opening
2
Open
3
Entry Only
4
Exit Only
5
Two-way Automatic
6
Night Service opening/closing
7
Common
8
RESET
).
.
.
tab. 2
fi g. 2
(
)
4

Publicité

loading