ENGLISH
the permanent display of the relative icon
this event, the appliance automatically stops the
motors and opens the by-pass valve to ensure that
there is however at least some air circulation. This
signal is interrupted when the filter maintenance or
cleaning procedure is being carried out.
Error warnings are indicated on the display by the
relative codes (ER01, ER02, etc...) and an acoustic
warning signal (a sequence of double BEEPs). These
warnings will remain in effect until the regular
operating conditions of the appliance have been
restored, or the appliance has been turned off. The
malfunctions will be indicated as:
ER01 : by-pass / de-frosting valve blocked;
ER02 : blockage of the fan motor intaking fresh air
from outside;
ER03 : blockage of the motor discharging the stale air
to outside;
ER04 : the remote control does not receive signals
from the appliance
ER05 : replace the filters
ER06 : the temperature sensor in the external fresh
air intake duct upsteam of the exchanger is not
active;
ER07 : the temperature sensor in the external fresh
air intake duct downsteam of the exchanger is not
active;
ER08 : the temperature sensor in the stale air outlet
delivery duct from the house downstream of the
exchanger is not active;
ER09 : the Relative Humidity sensor in the stale air
outlet delivery duct from the house upstream of the
exchanger is not active;
ER10 : the CO 2 sensor in the stale air outlet delivery
duct from the house upstream of the exchanger is not
active;
ER12 : the outside temperature is higher than the limit
value;
ER14 : the inside temperature is higher than the limit
value.
IMPORTANT
It should be noted that malfunction signals (ER01,
ER02 and ER03 codes) caused by critical appliance
malfunctions will cause the appliance to stop working
until the problem has been resolved. In this case, the
alarm will sound for 30 seconds. After this time it will
stop and an error message will remain on the
display.In other cases, once a problem has been
signalled, the appliance continues to run in the pre-
set function mode. The alarm will sound for 5
seconds. After this time it will stop and an error
message will remain on the display. In these
circumstances, the user will not be able to change the
operating mode(e.g. MAN or SUMMER). Pressing the
RESET buttons following the display of a malfunction
code will shut off the acoustic alarm; The display on
the remote control unit however will continue to show
the malfunction signal until the problem has been
resolved.
Reset error code
To stop the error code from being displayed (if the
disable remote control has not been carried out)
22
press the following keys one after the other:
. In
DISPLAY --> "-" (Minus) --> DISPLAY --> "+" (Plus).
After the RESET, the appliance resumes operation in
AUTO mode as per the initial standard parameters.
Any error messages is no longer displayed (of course
if the problem causing the malfunction has been
solved). Likewise, in the event of a power failure,
when power is restored, the appliance will return to
working in AUTO mode using its initial standard
parameter settings.

Maintenance/Cleaning

Replacement of the remote control batteries
open the battery compartment cover (fig.10);
insert 2 AA type batteries ensuring that the polarities
shown on the bottom of the compartment are
complied with ;replace the battery compartment
cover.