6.
EXAMPLE OF APPLICATION
GB
6.1 Automations in parallel
REM2
OUTSIDE
FC WEL2
WEL2
If the door has two overlapping leaves, two auto-
mations can be controlled in parallel [WEL 1] and
[WEL 2], using the connections indicated in the
drawings.
The movement of the two leaves is not synchro-
nised, the first leaf [WEL1] only closes when the
second leaf [WEL2] is completely closed.
The opening speed trimmer (VA) must be adjusted
in the same position in both automations.
The TC trimmer for the automation that closes the
first leaf [WEL 1] should be adjusted to minimum.
For automatic closing of the first leaf [WEL1], a limit
switch must be installed that will be activated when
the second leaf [WEL2] is closed. Connect the limit
switch as shown in the diagram.
Note: the closure limit switch [FC WEL2] is not
supplied by us with automations and must be ap-
plied to the leaf.
REM2
OUTSIDE
WEL2
In case of a swing door with two doors without
overlap, it is possible to control 2 automations
[WEL 1] and [WEL 2] concurrently, making sure
that the connections, as indicated in the figures,
have the following variants:
-
set the VA, VC, TC trimmers in the same po-
sitions.
-
do not install the limit switch FCWEL2.
The movement of the two doors is not synchroni-
sed.
EL12E - IP1892
REM1
OUTSIDE
WEL1
COMH
COMK
REM1
OUTSIDE
WEL1
COMH
COMK
OUTSIDE
INSIDE
REM
PAS
PAS
24 V
24 V
24 V
24 V
REM
OUTSIDE
INSIDE
REM
PAS
PAS
24 V
24 V
24 V
24 V
REM
10
WEL2
F2=F6,3A
WEL1
TC=MIN
F2=F6,3A
WEL2
F2=F6,3A
WEL1
F2=F6,3A