10.2 STANDBY FUNCTION

During operation (i.e. when the stove is on and in steady operating conditions) the stove can be switched off
when reaching the set room temperature (SET ROOM T.) and start again when reaching the set minimum room
temperature (START TEMP.).
To enable this function, go to the "STOVE SETTINGS MENU" following the "Procedure for accessing the menus"
described in paragraph 7.3 and press
and then press
Two parameters can be set:
-
The rst - ON/OFF - enables or disables the function;
-
The second de nes the temperature for restarting the stove.
When this function is active, the display shows the " " symbol.
"STAND-BY" is displayed when the room temperature is higher than the set "START TEMP.".

10.3 FROST PROTECTION FUNCTION

When the stove is off this function ensures the stove maintains the set room temperature (useful at night).
To access this function go to the "STOVE SETTINGS MENU" using the "Procedure for accessing the menus"
described in paragraph 7.3 and press
T." using the
button.
This menu has just one parameter, which can be set to "OFF" (function disabled) or alternatively a temperature
value (between 3° and 20°C) representing the temperature below which the stove will start.
When this function is active, the display shows the " " symbol.
"NIGHT STAND-BY" is displayed when the room temperature is higher than the set "NIGHT SET T".

10.4 "ECONOMY" FUNCTION

This is used to set the stove's maximum operating output in automatic mode. The set power level will never be
exceeded, thus keeping fuel consumption under control.

10.5 RESTARTING AFTER A POWER FAILURE

In the event of momentary power failures, the stove will restart automatically when power returns, if the conditions
are right. If such conditions are not ful lled, the display will show "Black Out Alarm" and the stove must be reset
manually as described in chapter 12.

10.6 READING THE OPERATING HOURS

The display can show total stove operating hours or the number of hours remaining before recommended
maintenance is required (to be performed by the Service Centre).
Pressing and holding the
the
button will display the REMAINING HOURS for a few moments.

10.7 PELLET LEVEL FUNCTION

The pellet stove is provided with a device for the detection of the reserve level of the pellet tank. When this value
is reached, the words 'LOW PELLET' will be displayed cyclically and an acoustic signal will be uttered.
We suggest you to re ll the pellet tank before it is completely empty.

10.8 OPERATION WITH ROOM THERMOSTAT

After having connected the room thermostat, when this is activated the stove will go to the lowest power
level (minimum output) while otherwise maintaining standard operation. The display will show the message
"THERMOSTAT ON" or alternatively the two temperature values will ash.

10.9 "EASY CLEAN" FUNCTION

This function is used to clean the stove by reducing the amount of ash dispersed in the room.
During this operation the ue gas fan operates at maximum speed, thus preventing ash from leaving the rebox.
It can only be activated when the stove has cooled down completely and is off.
When the stove is OFF, press the
switch off automatically after a preset cycle).
To stop the operation manually, press the
00 477 3370 - 09/2014 - PN - Italy
USE AND MAINTENANCE
. Use the arrow buttons to scroll until the display shows "STAND-BY"
.
. Use the arrow buttons to scroll the menu and select "NIGHT SET
button will display the TOTAL HOURS for a few moments, while pressing and holding
button for 2 seconds (the ue gas fan will start at maximum speed and will
OFF
OFF
button.
57

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ecofire

Table des Matières