10.2 STANDBY FUNCTION

During operation (i.e. when the stove is on and in steady operating conditions) the stove can be switched off
when reaching the set room temperature (SET ROOM T.) and start again when reaching the set minimum room
temperature (START TEMP.).
To enable this function, go to the "STOVE SETTINGS MENU" following the "Procedure for accessing the menus"
and press
. Use the arrow buttons to scroll until the display shows "STAND-BY" and then press
Two parameters can be set:
When this function is active, the display shows the " " symbol.
"STAND-BY" is displayed when the room temperature is higher than the set "START TEMP.".

10.3 FROST PROTECTION FUNCTION

When the stove is off this function ensures the stove maintains the set room temperature (useful at night).
To access this function go to the "STOVE SETTINGS MENU" using the "Procedure for accessing the menus"
described and press
This menu has just one parameter, which can be set to "OFF" (function disabled) or alternatively a temperature
value (between 3° and 20°C) representing the temperature below which the stove will start.
When this function is active, the display shows the " " symbol.
"NIGHT STAND-BY" is displayed when the room temperature is higher than the set "NIGHT SET T".

10.4 "ECONOMY" FUNCTION

This is used to set the stove's maximum operating output in automatic mode. The set power level will never be
exceeded, thus keeping fuel consumption under control.

10.5 RESTARTING AFTER A POWER FAILURE

In the event of momentary power failures, the stove will restart automatically when power returns, if the conditions
manually as described.

10.6 READING THE OPERATING HOURS

The display can show total stove operating hours or the number of hours remaining before recommended
maintenance is required (to be performed by the Service Centre).
Pressing and holding the
the
button will display the REMAINING HOURS for a few moments.
10.7 STARTING AND SWITCHING OFF THE STOVE USING THE REMOTE DEVICE (only
where avaiable)
remote contact stops the stove (for example, when reaching the set temperature). The display shows "REMOTE
STAND-BY". Opening the contact starts the stove again. The function is disabled if the OFF button is pressed
(switching the stove off) in any of the following stages: AWAITING FLAME, FLAME ON, FIRE ON, REMOTE
STAND-BY.

10.8 OPERATION WITH ROOM THERMOSTAT

After having connected the room thermostat, when this is activated the stove will go to the lowest power
level (minimum output) while otherwise maintaining standard operation. The display will show the message

10.9 "EASY CLEAN" FUNCTION

This function is used to clean the stove by reducing the amount of ash dispersed in the room.
It can only be activated when the stove has cooled down completely and is off.
When the stove is OFF, press the
switch off automatically after a preset cycle).
To stop the operation manually, press the
. Use the arrow buttons to scroll the menu and select "NIGHT SET T." using the
button will display the TOTAL HOURS for a few moments, while pressing and holding
OFF
button.
OFF
.
button.