INSTALLATION
6.3
PLUMBING SYSTEM
Connection to the plumbing system and the plumbing system must be in compliance with current national laws
and standards, and realized by quali ed personnel.
1. Make the water connections to the boiler body as described on the datasheet in the Product Booklet.
2. Make sure that all the control and safety devices including those supplied with the stove are installed
correctly (safety and heat exhaust valves).
You MUST NOT insert devices that completely close the heating system (zone valves). For safety reasons, the
pump must ALWAYS run while the stove is on, dispersing the heat produced. If there is too much ambient heat,
reduce the volume of the ame, if necessary put it out.
IN order to service the plumbing connections for easily accessing it:
• Open the door (1).
• Unscrew the front xing screws (2A-2B)
• Remove the front (2)
• Unscrew the front screws securing the right ank (3A-3B)
• Unscrew the rear screws of the right side mounting (3C-3D)
• Remove the right side (3)
• Unscrew the screws of the rear seatback
• Remove the rear seat backrest (4)
2
(3A)
(2A)
3
(2B)
1
(3B)
4
(3C)
3
(3D)
31