Fault - Cause - Remedy

Fault
Cause
Green Power LED
No power supply
does not illuminate
(9 V) present
Printer prints rubbish
External prommer not
for connection type A
connected
or B
Fault during printing
LPT1 interface
while the external
(Centronics) can only
prommer is active
process printer or
(logging, hard copies,
prommer
etc.)
1.
LPT1 interface set
Prommer not working
incorrectly in
at LPT1 (Centronics)
CONFIG.SYS or
AUTOEXEC.BAT
3.
LPT1 interface set
incorrectly in
SETUP
5.
LPT1 interface is
switched inactive by
power management
function
8
External Prommer
Remedy
Plug the power supply
and cable into the
prommer
Connect external
prommer
Redirect print output
to file and print this
file at a later date
2.
Check
CONFIG.SYS or
AUTOEXEC.BAT
file
4.
Check SETUP of
PC (see PC manual)
6.
Address LPT1
interface again with
the PRINT
command
External Prommer
C79000-K8576-C120-02