NOTICE : Switch tether is factory set at 3" for sump use.
DO NOT change tether length.
AUTOMATIC FLOAT SWITCH
1. Install pump following installation and operating instructions.
2. Automatic float switch is sealed and factory adjusted for
most home sumps. Turn-on water level is 10" - 12" above
pump base. Turn-off water level is 4" - 6".
3. Be sure float clearance is at least 8". For best performance,
the sump diameter must be 14" and the sump depth must be
18".
4. Plug piggyback switch cord into 115V AC outlet. Then, plug
pump into piggyback switch cord.
NOTICE : Minimum recommended turn-off level is 2" above
pump base.
Do not allow cord to interfere with float control motion or to
drape over pump motor. With electrician's tape, secure cord
to discharge pipe for cord protection.
Hazardous Voltage. Can cause serious or fatal electrical shock. Disconnect power to pump before servicing.
SYMPTOM
Motor does not run.
Motor hums but flow
is reduced or no flow
Runs continuously
NOTICE
: A plugged screen can be mistaken for a faulty switch.
Unlike other pumps, screen and impeller design of pump can pro-
vide significant flow, even when screen is nearly plugged. If pump
For parts or assistance, call Flotec Customer Service at
AUTOMATIC FLOAT SWITCH
1. Fill sump with 12"-14" of water to check operation and tight-
2. Check turn-off position. Turn-off will occur approx. 5" above
3. If the pump does not operate, check for:
TROUBLESHOOTING CHART
PROBABLE CAUSE(S)
Blown fuse
Tripped circuit
Disconnected plug
Corroded plug
Inadequate water level
Tripped overload
Defective switch
Defective motor
Float in wrong position
Impeller jammed
Plugged check valve
Blocked screen
Line leak
Worn Impeller
Defective motor
Plugged screen
Defective switch
Float obstruction
RUNS CONTINUOUSLY or for EXTENDED PERIODS between
turn-offs – FIRST check for a DIRTY SCREEN.
OPERATIONAL CHECK
ness of connections. During first automatic cycle, it may take
30 seconds or more before pump is primed and pumping.
Turn-on will occur approx. 11" above pump base.
pump base.
an obstructed float switch
a blown fuse
proper voltage.
REPAIR PARTS LIST
Description
Discharge Connector -
1-1/2" (incl. 2 clamps)
Power Cord
Automatic Float Switch
Screen
CORRECTIVE ACTION
Replace.
Reset.
Reinstall.
Clean prongs.
Add water and test.
Allow pump to cool.
Adjust float; replace switch.
Replace pump.
See Automatic Float Switch section.
Unplug pump and unclog.
Unplug pump and unclog.
Unplug pump and clean screen.
Unplug pump and repair.
Unplug pump and replace pump impeller.
Replace pump.
Unplug pump and clean screen.
Replace switch.
See Automatic Float Switch section.