Display
REAL
3 0 0
o f f
11. Adjusting settings
a) Navigating the settings menu
To enter the settings menu:
1. Press and hold buttons 1 and 3 at the same time for more than 3 seconds.
If a passcode has been set, "PSd" will show on the display. You must first enter the passcode to access the
settings menu. For further information, see section "g) Setting a passcode "PSd"" on page 33.
2. Press shortcut key 1 or 3 to navigate the settings menu.
3. Press TEMP ▲or ▼to adjust values.
4. Press shortcut key 2 to save settings and exit the settings menu.
Description
Timer function
C
• In this example a timer has been set for 20 seconds.
• The air gun will stop heating after 20 seconds then blow non-heated air
2 0
until it has been cooled to <100 °C.
Standby
• In this state you can adjust settings without activating the air gun.
• The air gun will enter standby when the temperature drops <100 °C.
• The air gun will start working after removing the handle from the holder.
Auto-sleep
• The workstation will enter sleep mode after 30 minutes in standby mode.
• Press any button to resume use.
Button
Description
1
Up
2
Save value and exit settings menu
3
Down
▲
Increase value
▼
Decrease value
31