Commissioning/start-up
NOTE
Never connect the pump to a dimmer. Otherwise the pump will be destroyed.
Switching ON/OFF
• Switching on: Plug the power plug into the outlet.
– The unit switches on immediately.
• Switching off: Pull the power plug from the outlet.
Environmental Function Control (EFC)
When started up, the pump automatically performs a pre-programmed self-test (En-
vironmental Function Control (EFC)). The pump detects if it is running dry / blocked
or submerged. The pump switches off automatically after approx. 90 seconds if it
runs dry/is blocked. In the event of a malfunction, disconnect the power supply and
"flood the pump" or remove the obstacle. Afterwards, the unit can be restarted.
Maintenance and cleaning
NOTE
Do not use aggressive cleaning agents or chemical solutions. These agents can dam-
age the housing, impair the function of the device and harm animals, plants and the
environment.
Only use clear water and a soft brush to clean the unit.
Cleaning the device
Recommendation regarding cleaning:
• Clean the unit as required, but at least twice a year.
• When cleaning the pump, pay particular attention to the impeller unit and the
pump housing.
• Pool water or salt water can impair the appearance of the unit. Such impairments
are excluded from the guarantee.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
EN
31