B, D
• Ensure that the power cables and mains sockets are at least 2 m from the water.
• For installation of the pump in a pump chamber (recommended):
– For a swimming pond or pool frequented by swimming people, install the pump
chamber at least 2 m from the water.
– Install the pump horizontally.
– Screw the stand to the floor of the pump chamber to ensure the stability of the
pump.
• For installation of the pump without a pump chamber:
– Place the pump horizontally on a stable, mud-free surface.
– Ensure secure and stable positioning of the pump.
• Only operate the pump when it is fully submerged.
• Pool water or salt water can impair the appearance of the unit. Such impairments
are excluded from the guarantee.
Dry installation of the pump
C
• Ensure that the power cables and mains sockets are at least 2 m from the water.
• For a swimming pond or pool frequented by swimming people, install the pump at
least 2 m from the water.
• Place the pump horizontally on a stable surface.
• Ensure secure and stable positioning of the pump. If necessary, screw the stand to
the ground.
• Protect the pump from direct sunlight.
• Adhere to the maximum permissible ambient temperature. If necessary, provide
forced cooling. (→ Technical data)
Connecting the pressure side/suction side
E
• Only remove the protective cap just before you connect the pipe or hand guard.
• The position of the pump outlet can be changed. The pump casing can be turned to
achieve a different position.(→ Turning the pump casing to achieve a different po-
sition )