Télécharger Imprimer la page

Pentair Sta-Rite S20P4JP10221 Notice D'installation Et De Fonctionnement page 2

Publicité

Safety
Table of Contents
. . . . . . . . . . . . . . . . . . . . . . . . . . 3
Rotation – (3 Phase only) . . . . . . . . . . . . . . . . . . 3
Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable Splicing . . . . . . . . . . . . . . . . . . . . . . . . . . 7
. . . . . . . . . . . . . . . . . . . . . . . . . .
Effluent Applications . . . . . . . . . . . . . . . . . . . . . .
C onnecting To Tank / Water System . . . . . . . . . .
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . .
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Important Safety Instructions
SAVE THESE INSTRUCTIONS - This manual
contains important instructions that should be
followed during installation, operation, and
maintenance of the product. Save this manual for
future reference.
This is the safety alert symbol. When you see
this symbol on your pump or in this manual, look
for one of the following signal words and be alert
to the potential for personal injury!
indicates a hazard which, if not
avoided, will result in death or serious injury.
indicates a hazard which, if not
avoided, could result in death or serious injury.
indicates a hazard which, if not
avoided, could result in minor or moderate injury.
NOTICE addresses practices not related to
personal injury.
To avoid serious or fatal personal injury and
possible property damage, carefully read and
follow the safety instructions.
Hazardous voltage. Can shock, burn
or cause death. To avoid dangerous or fatal electric
shock hazard, use pump only in a water well.
Risk of electrical shock. Do not
install this pump in any pond, river, or other open
body of water that could be used for swimming
or recreation. Do not swim, wade or play in a
body of water in which a submersible pump has
been installed.
Electrical Code, Canadian Electrical Code, and
local codes (as applicable) for all wiring.
installing or servicing pump.
power supply match motor nameplate voltage
Hazardous pressure.
conditions, submersible pumps can develop
valve capable of passing entire pump flow at
. . . . . . . . . . . . . . . 2
when using a pre-charged pressure tank.
pump, pressure tank, piping, or any other system
component containing water to freeze. Freezing
may damage system, leading to injury or flooding.
Allowing pump or system components to freeze
will void warranty.
California Proposition 65 Warning
contain chemicals known to the State of California to
cause cancer, birth defects or other reproductive harm.
Electrical Grounding Information
kill. To reduce the risk of electrical shock during pump
operation, ground and bond the pump and motor as
follows:
Allowing pump or system components to freeze will
void warranty.
Test well water for purity before using well. Call your
local health department for testing procedure.
During installation, keep well covered as much
as possible to prevent leaves and foreign matter
from falling into well. Foreign objects in well can
contaminate the water and cause serious mechanical
damage to the pump.
Pipe joint compound can cause cracking in plastics.
joints in plastic pipe or when connecting pipe to
thermoplastic pumps.
Risk of freezing. Do not allow
This product and related accessories
Hazardous voltage. Can shock, burn, or
parts of the assembly other than the pump, bond
together all metal parts accessible at the well head
(including metal discharge pipe, metal well casing,
at least as large as the power cable conductors
running down the well to the pump's motor.
conductor to the grounding means provided with
terminal, the grounding conductor on the pump
be the conductor having green insulation; it may
also have one or more yellow stripes.
conduit that carries power cable conductors.
a copper conductor from the pump, motor, and
conduit to the grounding screw provided within
the supply-connection box wiring compartment.
This conductor must be at least as large as the
circuit conductors supplying the pump
2

Publicité

loading