ENGLISH
Open the cover (29) and check that the recovery water tank (31) is empty, otherwise empty it with the drain hose (10).
Carefully lift the tank (31).
WARNING!
Pay attention when using sulphuric acid, as it is corrosive. If it comes in contact with skin or eyes, rinse
thoroughly with water and consult a physician.
Batteries have to be filled in a well-ventilated area. Wear protective gloves.
Fill up the battery cells with sulphuric acid for batteries (density 1.27 to 1.29 kg at 25°C) in accordance with the
instructions shown in the Battery Manual. The correct quantity of sulphuric acid is shown in the Battery Manual.
To avoid damaging the floor, dry with a cloth both acid and water on the top of the batteries after charging.
Let the batteries rest and fill in with sulphuric acid in accordance with the instructions shown in the Battery Manual.
Charge the batteries (see the procedure in Maintenance chapter).
BATTERY CHARGER SETTING
The charger default setting is common position for AGM,Gel,SLA,VRLA from factory
If needed use WET position only for lead batteries. Please contact dealer.
PRE-OPERATION CHECKS
Sweep the outside of the machine.
Make sure the voltage of machine conforms to local voltage.
Check that squeegee is properly installed.
Check that brush / pad is properly installed.
INSTALLING PAD DRIVER OR BRUSH
Ensure that the machine is turned off.
Lower brush head assembly to the floor by stepping on the foot pedal and pushing pedal forward.
Tilt the machine backward to access the drive motor hub.
NOTE
Remove the squeegee assembly prior to tilting the machine backwards. It makes the process faster and easier.
WARNING!
Do not keep the machine tilted back for a long time. This could cause battery acid to leak from the batteries.
If using a pad driver, first attach the appropriate pad to the pad driver surface.
Mount the pad driver or brush to the drive motor hub by lining up the three studs with the three holes in the drive motor
18
USER MANUAL