Terms And Abreviations - Chauvin Arnoux CA 6470 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

7 TERMS AND ABREVIATIONS

mΩ Ω Ω Ω
: Low resistance / continuity measurement
3 poles
: Earth measurement with 2 auxiliary rods
ρ ρ ρ ρ
: Ground resistivity per Schlumberger method – expressed in Ω.m
s
ρ ρ ρ ρ
: Ground resistivity per Wenner method – expressed in Ω.m
W
d, A
: Distances to be programmed to calculate resistivity and according to
method
H
: H terminal
S
: S terminal
ES
: ES terminal
E
: H terminal
EARTH
: Earth measurement
EARTH COUPLING
: Earth coupling measurement
Usr
: Frequency selected by user
U
Voltage generated by device across terminals H and E (16V or 32V)
OUT
U
: Voltage measured or generated across H and E terminals
H-E
U
: Voltage measured across S and E terminals
S-E
U
: Voltage measured across S and ES terminals
S-ES
U
« NOISE » and
: Spurious voltage measured across H and E terminals and its frequency
H-E
f
U
« NOISE » and
: Spurious voltage measured across S and E terminals and its frequency
S-E
f
R+
: Resistance measured with positive polarity current
R-
: Resistance measured with negative polarity current
R
: Mean resistance of R+ and R-
f
: Measurement frequency
mesure
R∆ ∆ ∆ ∆ 0
: Cord compensation resistance
I
: Measurement current across H and E terminals
H-E
R
: Resistance of rod E
E
R
: Resistance of rod H
H
R
: Resistance of rod S
S
R
Resistance of rod ES
SES
R
: Resistance across rods S and ES (used for resistivity calculation)
S-ES
54

Publicité

Table des Matières
loading