Télécharger Imprimer la page

Oase BioPress 8000 Notice D'emploi page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
- GB -
Information about this operating manual
Please read the operating instructions and familiarise yourself with the unit prior to using it for the first time. Adhere to
the safety information for the correct and safe use of the unit.
Intended use
The BioPress 8000/12000 series, in the following text termed unit, is an enclosed pressure filter system with integrated
UVC clarifying unit for the bio-mechanical filtering of normal pond water at temperatures from + 4°C to + 35 °C. The
pressure filter system is only suitable for private use and must exclusively be used for cleaning garden ponds with or
without fish population. Operation of the pressure filter system is only permitted with the supplied filter pump Aquamax
Start (BioPress 8000 with Aquamax Start 3500 or BioPress 12000 with Aquamax Start 5500).
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and in the case of
misuse. If used for purposes other than that intended, our warranty and operating permit will become null and void.
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive, EMC directive (89/336/EEC) as well as the low voltage direc-
tive (73/23/EEC). The following harmonised standards apply:
EN 55014-2, EN 55015, EN 60598-1, EN 60335-1, EN 60335-2-41, EN 60598-2-1, EN 61000-3-2, EN 61000-3-3,
EN 61547
Signature:
Safety information
OASE has manufactured this unit to the current state of the art and the valid safety regulations. Despite of the above,
hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accordance
with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who cannot recog-
nise possible danger or who are not familiar with these operating instructions, are not permitted to use the
unit!
Please keep these operating instructions in a safe place! Also hand over the operating instructions when passing the
unit on to a new owner. Ensure that all work with this unit is only carried out in accordance with these instructions.
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected or
misused.
Attention! Dangerous ultra-violet radiation.
The radiation of the UVC lamp is dangerous to eyes and skin! For this reason, the unit can only be switched on with
the housing fitted (safety switch). Never operate the unit lamp outside of the filter housing. Never immerse the filter in
water! Always disconnect the power supply of these and all other units located in water prior to performing work on the
units! Only operate the units when plugged into an earthed socket. The latter must have been installed in accordance
with the valid national regulations. Ensure that the protective earth wire is led to the unit. Only use cables approved for
outside use. Never use installations, adapters, extension or connection cables without protective earth contact! The
cross section of power connection cables must not be smaller than the rubber cables identified with H05 RNF. Exten-
sion cables must meet DIN VDE 0620. Ensure that the units are supplied with a rated residual current of max. 30 mA
via a residual current-operating system (FI or RCD resp.). Electrical installations at garden ponds and swimming pools
must meet the international and national regulations valid for installers. Compare the electrical values of the power
supply with those on the type plate on the packaging or on the units. Protect the connection cable when burying to
avoid damage. Protect the plug connections and all connection points from moisture. Never operate the unit if the
cable or housing are defective! Disconnect the power! The power connection cables of these units cannot be replaced.
Replace the units (unit components) concerned if the cables are damaged. Do not carry or pull the units by their
connection cables. Never open the unit housings or their attendant components, unless this is explicitly mentioned in
the operating instructions. Never carry out technical changes to the units. Only use original spare parts and accesso-
ries for the units. Only allow authorised customer service outlets to perform repairs. For your own safety, consult a
qualified electrician if you have questions or encounter problems! Do not operate the units if persons are in the water!
Never run the units without water! Never use the pump for fluids other than water!
Attention! Never use the unit at a water pressure exceeding 2 m water column!
Ensure that no leaks at the filter can occur. Danger of completely emptying the pond.
Installation (A)
Oase recommends hoses suitable for a minimum pressure of 1 bar.
Cut the stepped hose adapters such that the connection opening coincides with the hose diameter (A1). This helps to
avoid pressure loss.
8

Publicité

loading

Ce manuel est également adapté pour:

Biopress 12000