Operating Limits; Minimum Average Water Temperature (Tw) [°C] - AERMEC FCX P Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

FCX P-PE-PO-PV
18.

OPERATING LIMITS

Maximum water inlet temperature (Tw)
Maximum water inlet temperature recommended
(Tw)
Maximum operating pressure
Environment temperature limits (Ta)
Relative humidity limits in the environment (R.H.)
Electric power supply
Standard main coil • Cooling circuit for double-circuit coils
Standard coil
Minimum water flow rate (Qw)
Maximum water flow rate (Qw)
Heating only coil (BV accessory) • Heating circuit for double-circuit coils
FCX
BV
Minimum water flow rate (Qw)
Maximum water flow rate (Qw)
Larger coil
Larger coil
Minimum water flow rate (Qw)
Maximum water flow rate (Qw)
Water temperature
In order to prevent air stratification in the envi-
ronment and thus, have better mixing, the fan coil
should not be supplied with water that is hotter
than 65 °C. Using water at a very high tempera-
Minimum average water temperature
If the fan coil runs continuously in cooling
mode in an environment with high relative
humidity, condensate may form on the air
flow. This condensate could drip onto the
floor and onto any underlying objects. To
prevent condensation phenomena on the
external structure of the appliance with the
fan running, the average water temperature
Wet-bulb temperature
of ambient air (Ta) [°C]
IFCXPLJ 1412 - 6456063_01
FCX
°C
°C
bar
°C
FCX
l/h
l/h
l/h
l/h
FCX
l/h
l/h
ture can cause creaking due to the heat expansion
of the elements (plastic and metal). However, this
does not cause damage to the unit unless the
maximum operating temperature is exceeded.
must not drop below the limits indicated in
the table. These limits depend on the tem-
perature and humidity conditions of the
room air. These limits refer to operation with
the fan running at minimum speed.
Condensation may form in the event the fan
is off for a prolonged period and cold water
flows in the coil; therefore, we recommend
15
17
19
21
23
17
22
32
36
42
24
34
44
0 < Ta < 45
R.H. < 85%
230V ( ±10% ) ~ 50Hz
17
22
32
36
42
100
100
100
100
150
750
750
750
750
1100 1100 1100 2200 2200 2200
17
22
32
36
42
117
122
132
132
142
50
50
50
50
50
400
400
400
400
400
24
34
44
150
150
150
1100 1100
1100 1100
Dry-bulb temperature of ambient air (Ta) [°C]
21
23
25
3
3
3
3
3
3
3
3
3
6
5
4
-
8
7
MINIMUM AVERAGE WATER TEMPERATURE (Tw) [°C]
EN
50
56
62
82
54
64
84
80
65
8
50
56
62
82
150
150
300
300
50
56
62
82
142
142
162
162
50
50
100
100
400
400
900
900
54
64
84
150
300
300
2200 2200
installing the 3-way valve (accessory).
27
29
3
3
3
3
3
3
3
3
6
5
102
102
300
102
162
100
900
31
3
3
3
3
5
25