english
1
intenDeD uSe
2503 boost Close is designed for use with type 6712 and type
6724 valves.
▶ Use according to the permitted data, operating conditions and
conditions of use specified in the contract documents and opera-
ting instructions.
▶ Do not use the device outdoors.
▶ The device may be used only in conjunction with third-party
devices and components recommended and authorised by
Bürkert.
▶ Correct transportation, correct storage and installation and
careful use and maintenance are essential for reliable and
problem-free operation.
▶ Use the device only as intended.
2
baSiC SaFety inStruCtionSe
These safety instructions do not consider any contingencies or inci-
dents which occur during installation, operation and maintenance.
risk of injury from high pressure.
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
risk of electric shock.
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
Risk of burns/Risk of fire if used continuously through hot device
surface.
▶ Keep the device away from highly flammable substances and media
and do not touch with bare hands.
general hazardous situations.
▶ Do not make any internal or external changes on the device and do
not subject it to mechanical stress.
▶ Secure the system from unintentional actuation.
▶ Only trained technicians may perform installation and maintenance
work.
▶ The valves must be installed in accordance with the regulations
applicable in the country.
▶ After an interruption, ensure that the process is restarted in a con-
trolled manner.
▶ Observe the general rules of technology.
3
teChniCal Data
3.1
Conformity
Type 2503 conforms with the EU Directives according to the EU
Declaration of Conformity (if applicable).
3.2
Standards
The applied standards, which verify conformity with the EU Directives,
can be found on the EU-Type Examination Certificate and / or the EU
Declaration of Conformity (if applicable).
3.3
general technical data
type
Valve circuit function
Seal material
Valve operating voltage
Orifice
Extended pressure range with
electronics
3)
Permissible return pressure /
dynamic pressure in the valve
type
Valve circuit function
Seal material
Valve operating voltage
Orifice
Extended pressure range with
electronics
3)
Permissible return pressure /
dynamic pressure in the valve
1) with FKM and FFKM the electronics reduces the life time significantly.
2) 3/2-way valves can be connected. In this case, the leak-tightness of the
normally closed connection (NC) is increased. The leak-tightness of the
normally open connection (NO) remains unchanged.
3) Note! If the electronics operating voltage is switched off, the pressure
values drop to the values without electronics specified in the data sheet.
6712
A
EPDM
(not suitable for FKM and FFKM )
1)
12...24 V
0.8 mm
0...6 bar
Max. 5 bar
6724
A, T
2)
EPDM, FKM, FFKM
12...24 V
1.2 mm
Vac...7 bar
Max. 5 bar
4
inStallation
NOTE
3/2-way valves can be connected. in this case, the leak-tightness
of 'the normally closed' connection (nC) is increased. the
leak-tightness of the 'normally open' connection (no) remains
unchanged.
DANGER
risk of injury from high pressure
If the operating voltage (+U
) is switched off (e.g. at the end of
B
operation or due to an emergency stop), the 'active seal effect'
is no longer applicable. The pressure values drop to the default
values of the applied valve (see data sheet).
▶ Pay attention to the maximum permissible return pressure values
and dynamic pressure values stated in the table „3 Technical data".
4.1
Connecting the electronics
Identification: see labeling on the electronics.
+ signal IN (
gray
)
black
GND (
)
+U
(red)
B
Fig. 1:
Connecting the valve
input side electronics (3 wires)
Connection
Color
Description
Control signal
+signal IN
gray
(digital)
GND
black
Ground
Valve operating
+U
red
voltage
B
output side electronics (2 wires, valve plug)
Connection
Color
-
black
+
red
4.2
Connecting the valve
Pressure connection at the valve inlet (NC connection):
Betriebsspannung
Druckanschluss
Fig. 2:
Connecting the valve
Installation instructions for type 6712 and type 6724 valves
can be found in the printed operating instructions or online
at:
www.buerkert.com
5
DeinStallation
Deinstallation instructions for type 6712 and type 6724
valves can be found in the printed operating instructions or
online at:
www.buerkert.com
6
tranSPortation, Storage, DiSPoSal
• Transport and store Type 6724 in shock-resistant packaging to
protect against moisture and dirt.
• Permitted storage temperature: –10 ... +65 °C.
• Dispose of the device and packaging according to the applicable
disposal and environmental protection regulations.
Type 2503
black
- (
)
+ (red)
Voltage
'low signal'
0...+2 V
'high signal'
+5...+24 V
0 V
+12...+24 V
(acc. to valve imprint)
Description
Valve connection -
Valve connection +
Betriebsspannung
Druckanschluss