Selecting The Anchors - Nussbaum POWER LIFT HF 4600 Manuel D'exploitation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

8.6

Selecting the anchors

Concrete quality min C20/25 normal reinforced
Rights reserved to make changes!
Hilti injection anchor
Concrete floor
Anchor
Drill depth (mm)
Minimum anchoring
depth (mm)
Component thickness
(mm)
Bore diameter (mm)
Attachment thickness
(mm)
Torque (Nm)
Total length (mm)
Thread
Part count
Follow the assembly instructions of the anchor manufacturer. Use longer
anchors for floor coverings (screed / tiles).
Similar value injection anchors from other manufacturers (with permis-
sion) in compliance with their specifications.
102
HF 4600
without floor cover
HIT-V-5.8 M16x200
Art.no. 956437
h
0
h
ef
h
min. 180
min
d
0
t
fix
T
inst
I
M
a
b
c
d
e
f
g
144
144
18
23
80
200
16
4
8
10
12
14
16
28
OPI-POWER LIFT HF 4600-V3.0-DE-EN-FR-ES-IT