TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult your
dealer or the HiKOKI Authorized Service Center.
Power tool
Symptom
Tool doesn't run
Tool suddenly stopped
Cannot be tilted
Sawblade is dull
Cannot cut with precision
Motor head cannot be
lowered
Possible cause
Trigger switch is in OFF position
The power cord is not plugged in properly.
Tool was overburdened.
The clamp lever has not been loosened.
The sawblade is worn down or missing
teeth.
Bolt is loose.
The sawblade has been installed in reverse. Install the sawblade in the correct direction.
The operation parts of the tool are not fully
fi xed.
Material cannot be fi xed in the correct
position.
Blade guard locking lever is not released.
Turn on the switch.
Plug the power cord correctly.
Get rid of the problem causing the
overburden.
Loosen the clamp lever and then tilt the tool.
After adjusting the loosened component,
make sure to tighten it once again.
Exchange with a new sawblade.
Tighten the bolt.
Fully fi x the clamp lever and bevel lock
knob.
Remove any foreign material from the fence
or turntable.
In some cases, proper position cannot be
fi xed due to a curve in the material.
Try to fi x a fl at surface with the fence or
turntable.
Release the blade guard locking lever and
then lower the motor head.