Fault
The pumps does not
start.
The pump delivers no
water.
The flow rate is too low.
The pump does not stop.
The pump stops running
(possible intervention of
the
thermal
overload
switch).

12. GUARANTEE

Any modification made without prior authorisation relieves the manufacturer of all responsibility. All the
spare parts used in repairs must be authentic and all accessories must be authorised by the
manufacturer, in order to ensure maximum safety of the machines and of the systems in which they may
be installed.
This product is covered by a legal guarantee (in the European Community for 24 months from date of purchase) against
all defects that can be assigned to manufacturing faults or to the material used.
The product under guarantee may, at discretion, either be replaced with one in perfect working order or replaced free of
charge if the following conditions are observed:
the product has been used correctly in compliance with the instructions and not attempt has been made to
repair it by the buyer or by third parties.
the product has been consigned to the outlet where it was purchased, attaching a document as proof of
purchase (invoice or cash register receipt) and a brief description of the problem found.
The impeller and parts subject to wear are not covered by the guarantee. Intervention under guarantee does not extend
the initial guarantee period in any way.
Possible Cause
A. The motor is not powered.
B. There is no water (pumps in alarm mode).
C. The pump is not enabled by the float.
A. The suction grid or piping are clogged.
B. The impeller is worn or stuck.
C. The head required is higher than the pump's
characteristics.
A. The suction grid is partially blocked.
B. The impeller or delivery pipe are partially
blocked or encrusted.
A. The pump is not disabled by the float.
A. The liquid to be pumped is too dense and
overheats the motor.
B. The water temperature is too high.
C. A solid object is blocking the impeller.
D. Power
supply
doesn't
nameplate's the data.
ENGLISH
comply
with
the
4
Solutions
A. Check the power supply.
B. Check the water level.
C. Make sure the float can move
freely.
A. Remove the obstruction.
B. Replace the impeller or remove
the obstruction.
A. Remove any obstruction.
B. Remove any obstruction.
A. Make sure the float can move
freely.
A.B.C.D. Disconnect the power cord,
correct the reason for overheating;
then wait until the pump is cooled
plug the cord and resume operation.