ƒ
Use only branded products with corrosion protection inhibitors!
ƒ
Comply with the chloride content of the top-up water according
to the manufacturer's instructions! Chloride containing soldering
pastes are not permitted!
ƒ
Follow the safety data sheets and manufacturer's instructions!
Salty fluids
CAUTION
Material damage due to salty fluids!
Salty fluids (e.g. carbonates, acetates or formates) are very cor-
rosive and can damage the pump!
ƒ
Fluid temperatures above 40 °C are not permitted for salty flu-
ids!
ƒ
Use a corrosion inhibitor and constantly check its concentration!
NOTICE
Use other fluids only after approval by WILO SE!
Installation and operating instructions Wilo-Stratos MAXO/-D/-Z
CAUTION
Material damage can occur due to the accumulation of
chemicals!
When changing, refilling or replenishing the fluid with additives,
there is a risk of material damage caused by the accumulation of
chemicals.
ƒ
Rinse the pump separately and thoroughly. Ensure the old fluid
has been completely removed from the interior of the pump!
ƒ
Remove pump before change in pressure flushes!
ƒ
For chemical flushing measures:
–
Remove the pump from the system for the duration of clean-
ing!
Drinking water pumps:
WARNING
Health hazard!
Because of the materials used, pumps of the Stratos
MAXO/ -D series are unsuitable for use in applica-
tions involving drinking water or foodstuffs.
The smart-pumps of the Stratos MAXO-Z series are coordinated
specifically for operating conditions in domestic hot water circula-
tion systems through a selection of materials and their design, tak-
ing account of the guidelines of the German Environmental Agency
(Umweltbundesamt):
en
33