The product is approved for use with batteries of type AAA.
3.3 Items supplied
Laser range meter, belt pouch, 2 batteries, quick-start operating instructions,
manufacturer's certificate, safety instructions
Other system products approved for use with this product can be found at
your local Hilti Store or online at: www.hilti.group | USA: www.hilti.com
4
Technical data
Power supply (2 x)
Measuring range
Distance measurement accuracy
IEC 60529 protection class (dustproof and
sprayproof)
Operating temperature
Recommended temperature range for transport and
storage
Weight in accordance with EPTA procedure 01
Battery (2 x)
Battery life (number of measurements), up to
Laser deactivation after
Device shutdown after
5
Operation
5.1 Preparations at the workplace
5.1.1 Inserting the batteries
Make sure that battery polarity is correct. Change the batteries only as
a pair. Do not use damaged batteries.
▶ Open the battery compartment and insert the batteries.
5.1.2 Switching the product on and off
1. Short-press the ON / Delete / OFF button to switch the product on.
2. Press the ON / Delete / OFF button for 2 seconds to switch the product
off.
5.1.3 Switching the acoustic signal on and off
▶ Simultaneously press the Area measurement / Units button and the
ON / Delete / OFF button for 2 seconds to switch the acoustic signal on
or off.
*2190183*
2
2190183
PD-S
1.5 V
0.2 m ... 60 m
±1.5 mm
IP 54
−10 ℃ ... 50 ℃
−25 ℃ ... 70 ℃
95 g
AAA
10000
90 s
180 s
3
7
English
5