SORHEA
 Detail for pole-mounted columns
Seal the 4 anchor rods in solid concrete, taking care to install them in a vertical position using the
provided sealing template.
Position the floor socket seal so that it is oriented the same way as the beam.
Pay attention to the position of the cable's entrance.
The fixing model holding the base assembly in place also serves as the sealing template.
=
200 mm / 7.9 in
250 mm / 9.8 in
 Pole-mounted columns
1. Place the screws M5x30 in frame grooves.
2. Place the spacers at the back of the column, then fasten the assembly on the pole.
4 anchors rods
M16x250
Cable entry
Hole 70 mm
/ 2.7
=
Effective zone of
beams:  90°